正(zheng)壓(ya)型(xing)防爆櫃(gui)采(cai)用(yong)主(zhu)、副腔結(jie)構(gou);主腔(qiang)為正(zheng)壓(ya)腔(qiang),內裝用戶所需的(de)電器元件和(he)防爆必(bi)須的檢壓(ya)傳感(gan)系(xi)統(tong)、通(tong)風布氣(qi)系(xi)統(tong)、氣(qi)壓(ya)調(tiao)節系(xi)統(tong)等(deng),副腔內裝防爆換(huan)氣自(zi)控(kong)系(xi)統(tong)、防爆電(dian)源(yuan)自切(qie)換(huan)系(xi)統(tong)、防爆報(bao)警系(xi)統(tong)、防爆壓(ya)力(li)顯示系(xi)統(tong)、進(jin)出氣(qi)源(yuan)連接(jie)口、自(zi)供(gong)氣規格(ge)產品(pin)的副腔內還裝有防爆供(gong)氣裝置。它的(de)工(gong)作(zuo)原(yuan)理是(shi):在(zai)設備(bei)在(zai)開(kai)啟(qi)前(qian),首(shou)先要(yao)進(jin)行(xing)換氣程(cheng)序。所謂換(huan)氣(qi)是(shi)指(zhi)足(zu)量(liang)的(de)保護氣體(ti)通(tong)過(guo)正(zheng)壓(ya)外殼(ke)及管道,是(shi)爆炸(zha)性氣體(ti)混(hun)合(he)物(wu)降至(zhi)爆(bao)炸下限(xian)以(yi)下的(de)過(guo)程。 換(huan)氣過(guo)程:
換(huan)氣過(guo)程以(yi)小換(huan)氣量(liang)來(lai)實現。即進入(ru)正(zheng)壓(ya)型(xing)防爆櫃(gui)外殼(ke)及管道容(rong)積(ji)的(de)氣(qi)量(liang)值(zhi)進行(xing)沖洗(xi),使(shi)殼(ke)體(ti)內無(wu)爆炸性氣體(ti)混(hun)合(he)物(wu)後才能(neng)通(tong)電(dian)。當(dang)進(jin)入(ru)正(zheng)壓(ya)型(xing)防爆櫃(gui)外殼(ke)及管道的小流(liu)量(liang)確(que)定後(hou),為達到小換(huan)氣量(liang)的(de)時間(jian)稱小換(huan)氣時間(jian)。換(huan)氣(qi)過(guo)程只(zhi)須控制小換(huan)氣時間(jian)即可(ke)完成。
對(dui)於在(zai)換(huan)氣過(guo)程中(zhong)實現控制目(mu)的的電氣系(xi)統(tong),如(ru)裝在(zai)危險(xian)環境(jing),應(ying)采(cai)用(yong)適(shi)合(he)的防爆結(jie)構(gou)型式(shi),保證(zheng)正(zheng)壓(ya)型(xing)電(dian)氣(qi)設備(bei)的(de)安(an)全(quan)性。
正(zheng)壓(ya)型(xing)防爆櫃(gui)在(zai)啟(qi)動、運(yun)行(xing)時,會有氣壓(ya)不足(zu)的(de)情(qing)況。所以(yi)正(zheng)壓(ya)型(xing)電(dian)氣(qi)設備(bei)應(ying)設置(zhi)補(bu)氣(qi)及控制系(xi)統(tong),保證(zheng)低於(yu)工作(zuo)壓(ya)力(li)時(shi),進行(xing)自動補(bu)氣(qi);壓(ya)力(li)再(zai)降低時(shi),進行(xing)報(bao)警;壓(ya)力(li)降低至(zhi)小值(zhi)時,應(ying)自(zi)動切(qie)斷電源(yuan)系(xi)統(tong)。整(zheng)個(ge)控(kong)制過(guo)程要(yao)運(yun)行(xing)可(ke)靠(kao)。
要(yao)研究(jiu)保護氣體(ti)切(qie)斷後殼體(ti)內部(bu)件(jian)的表面溫(wen)度(du),當(dang)內部(bu)安(an)裝有發熱(re)元件(jian)時(shi),當(dang)元(yuan)件(jian)的表面溫(wen)度(du)超過(guo)規定的(de)溫度(du)組(zu)別(bie)時(shi),應(ying)采(cai)取氣密(mi)或澆(jiao)封防爆措施(shi)加以(yi)保護。